AEMO Description

DISPATCHINTERCONNECTORRES sets out MW flow and losses on eac

Note that the provided table descriptions are truncated by AEMO.

Total Schema Versions 1
Combined Rows 188,442
Combined Size 6.42 MiB
MMS Table dispatchinterconnectorres
Unified View nemwebviews.dispatch__interconnectorres

Schema Evolution

Column Type Description 59f7a933
DISPATCHINTERVAL Nullable(Float64) Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP. ✓
EXPORTGENCONID LowCardinality(String) Generic Constraint setting the export limit ✓
EXPORTLIMIT Nullable(Float64) Calculated export limit applying to energy only. ✓
FCASEXPORTLIMIT Nullable(Float64) Calculated export limit applying to energy + FCAS. ✓
FCASIMPORTLIMIT Nullable(Float64) Calculated import limit applying to energy + FCAS. ✓
IMPORTGENCONID LowCardinality(String) Generic Constraint setting the import limit ✓
IMPORTLIMIT Nullable(Float64) Calculated import limit applying to energy only. ✓
INTERCONNECTORID LowCardinality(String) Interconnector identifier ✓
INTERVENTION Nullable(Float64) Intervention case or not ✓
LASTCHANGED Nullable(DateTime64(3)) Last changed. ✓
LOCALLY_CONSTRAINED_EXPORT Nullable(Float64) Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints ✓
LOCALLY_CONSTRAINED_IMPORT Nullable(Float64) Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints ✓
LOCAL_PRICE_ADJUSTMENT_EXPORT Nullable(Float64) Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0) ✓
LOCAL_PRICE_ADJUSTMENT_IMPORT Nullable(Float64) Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0) ✓
MARGINALLOSS Nullable(Float64) Marginal loss factor. Use this to adjust prices between regions. ✓
MARGINALVALUE Nullable(Float64) Shadow price resulting from thermal or reserve sharing constraints on Interconnector import/export (0 unless binding) - NEMDE Solution InterconnectorSolution element “Price” attribute ✓
METEREDMWFLOW Nullable(Float64) Metered MW Flow from SCADA. ✓
MWFLOW Nullable(Float64) Target MW Flow for next 5 mins. ✓
MWLOSSES Nullable(Float64) Calculated MW Losses ✓
RUNNO Nullable(Float64) Dispatch run no; always 1 ✓
SETTLEMENTDATE Nullable(DateTime64(3)) Market date starting at 04:05 ✓
VIOLATIONDEGREE Nullable(Float64) Degree of violation on interconnector constraints ✓
processed_at DateTime64(3) ✓
source_zip String ✓

Schema Versions

Version Rows Size
59f7a933 188,442 6.42 MiB