interconnectorsolution

pd7day__interconnectorsolution

AEMO Description

PD7DAY intereconnector solution

Note that the provided table descriptions are truncated by AEMO.

Total Schema Versions 1
Combined Rows 1,867,488
Combined Size 58.82 MiB
MMS Table pd7day_interconnectorsolution
Unified View nemwebviews.pd7day__interconnectorsolution

Schema Evolution

Column Type Description 658655df
EXPORTCONSTRAINTID LowCardinality(String) Generic Constraint setting the export limit ✓
EXPORTLIMIT Nullable(Float64) Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit ✓
FCASEXPORTLIMIT Nullable(Float64) Calculated export limit applying to energy + Frequency Controlled Ancillary Services. ✓
FCASIMPORTLIMIT Nullable(Float64) Calculated import limit applying to energy + Frequency Controlled Ancillary Services. ✓
IMPORTCONSTRAINTID LowCardinality(String) Generic Constraint setting the import limit ✓
IMPORTLIMIT Nullable(Float64) Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow. ✓
INTERCONNECTORID LowCardinality(String) Interconnector identifier ✓
INTERVAL_DATETIME Nullable(DateTime64(3)) The unique identifier for the interval within this study ✓
INTERVENTION Nullable(Float64) Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run. ✓
LASTCHANGED Nullable(DateTime64(3)) Last date and time record changed ✓
LOCALLY_CONSTRAINED_EXPORT Nullable(Float64) Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints ✓
LOCALLY_CONSTRAINED_IMPORT Nullable(Float64) Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints ✓
LOCAL_PRICE_ADJUSTMENT_EXPORT Nullable(Float64) Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0) ✓
LOCAL_PRICE_ADJUSTMENT_IMPORT Nullable(Float64) Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0) ✓
MARGINALLOSS Nullable(Float64) Marginal loss factor at the cleared flow ✓
MARGINALVALUE Nullable(Float64) Marginal cost of Interconnector standing data limits (if binding) ✓
METEREDMWFLOW Nullable(Float64) SCADA MW Flow measured at Run start. For periods subsequent to the first period of a PD7DAY run, this value represents the cleared target for the previous period of that PD7DAY run. ✓
MWFLOW Nullable(Float64) Cleared Interconnector loading level (MW) ✓
MWLOSSES Nullable(Float64) Interconnector Losses at cleared flow ✓
RUN_DATETIME Nullable(DateTime64(3)) Unique Timestamp Identifier for this study ✓
VIOLATIONDEGREE Nullable(Float64) Violation of Interconnector standing data limits ✓
processed_at DateTime64(3) ✓
source_zip String ✓

Schema Versions

Version Rows Size
658655df 1,867,488 58.82 MiB

Last updated: 2026-07-16 05:00:09