participant_registration__dudetailsummary__7

AEMO Description

DUDETAILSUMMARY sets out a single summary unit table so redu

Note that the provided table descriptions are truncated by AEMO.

Total Schema Versions 1
Combined Rows 133,067
Combined Size 890.14 KiB
MMS Table dudetailsummary
Unified View nemwebviews.participant_registration__dudetailsummary__7

Schema Evolution

Column Type Description af53c352
ADG_ID LowCardinality(String) Aggregate Dispatch Group. Group into which the DUID is aggregated for Conformance. Null if DUID not aggregated for Conformance ✓
CONNECTIONPOINTID LowCardinality(String) Country wide - Unique id of a connection point ✓
DISPATCHSUBTYPE LowCardinality(String) Additional information for DISPATCHTYPE. For DISPATCHTYPE = LOAD, subtype value is WDR for wholesale demand response units For DISPATCHTYPE = LOAD, subtype value is NULL for Scheduled Loads. For DISPATCHTYPE = GENERATOR type, subtype value is NULL. ✓
DISPATCHTYPE LowCardinality(String) Identifies LOAD, GENERATOR or BIDIRECTIONAL. This will likely expand to more generic models as new technology types are integrated into the NEM ✓
DISTRIBUTIONLOSSFACTOR Nullable(Float64) The distribution loss factor to the currently assigned connection point ✓
DUID LowCardinality(String) Dispatchable Unit Identifier ✓
END_DATE Nullable(DateTime64(3)) End date for effective record ✓
IS_AGGREGATED Nullable(Float64) Whether the DUID is classified as an “Aggregated Unit” under the rules. This impacts the Minimum Ramp Rate calculation ✓
LASTCHANGED Nullable(DateTime64(3)) Last date and time record changed ✓
LOAD_MAXIMUM_ENERGY_PRICE Nullable(Float64) BDU only. Capped Offer/Bid Energy Price adjusted for TLF, DLF and VoLL for energy imports ✓
LOAD_MAX_RAMP_RATE_DOWN Nullable(Float64) BDU only. MW/Min. Registered Maximum Ramp Rate Down value accepted for Energy Offers or Bids for energy imports ✓
LOAD_MAX_RAMP_RATE_UP Nullable(Float64) BDU only. MW/Min. Registered Maximum Ramp Rate Up value accepted for Energy Offers or Bids for energy imports ✓
LOAD_MINIMUM_ENERGY_PRICE Nullable(Float64) BDU only. Floored Offer/Bid Energy Price adjusted for TLF, DLF and MPF for energy imports ✓
LOAD_MIN_RAMP_RATE_DOWN Nullable(Float64) BDU only. MW/Min. Calculated Minimum Ramp Rate Down value accepted for Energy Offers or Bids with explanation for energy imports ✓
LOAD_MIN_RAMP_RATE_UP Nullable(Float64) BDU only. MW/Min. Calculated Minimum Ramp Rate Up value accepted for Energy Offers or Bids with explanation for energy imports ✓
MAXIMUM_ENERGY_PRICE Nullable(Float64) Capped Offer/Bid Energy Price adjusted for TLF, DLF and VoLL ✓
MAX_RAMP_RATE_DOWN Nullable(Float64) Maximum ramp down rate for Unit (Mw/min) - from DUDetail table ✓
MAX_RAMP_RATE_UP Nullable(Float64) Maximum ramp up rate for Unit (Mw/min) - from DUDetail table ✓
MINIMUM_ENERGY_PRICE Nullable(Float64) Floored Offer/Bid Energy Price adjusted for TLF, DLF and MPF ✓
MIN_RAMP_RATE_DOWN Nullable(Float64) MW/Min. Calculated Minimum Ramp Rate Down value accepted for Energy Offers or Bids with explanation ✓
MIN_RAMP_RATE_UP Nullable(Float64) MW/Min. Calculated Minimum Ramp Rate Up value accepted for Energy Offers or Bids with explanation ✓
PARTICIPANTID LowCardinality(String) Participant that owns unit during effective record period ✓
REGIONID LowCardinality(String) Region identifier that unit is in ✓
SCHEDULE_TYPE LowCardinality(String) Scheduled status of the unit: ✓
SECONDARY_TLF Nullable(Float64) Used in Bidding, Dispatch and Settlements, only populated where Dual TLFs apply. For Bidding and Dispatch, the TLF for the generation component of a BDU, when null the TRANSMISSIONLOSSFACTOR is used for both the load and generation components. For Settlements, the secondary TLF is applied to all energy (load and generation) when the Net Energy Flow of the ConnectionPointID in the interval is positive (net generation). ✓
STARTTYPE LowCardinality(String) Unit start type. At this time restricted to Fast, Slow or Non Dispatched ✓
START_DATE Nullable(DateTime64(3)) Start date for effective record ✓
STATIONID LowCardinality(String) Station that unit is in ✓
TRANSMISSIONLOSSFACTOR Nullable(Float64) Used in Bidding, Dispatch and Settlements. For Bidding and Dispatch, where the DUID is a BDU with DISPATCHTYPE of BIDIRECTIONAL, the TLF for the load component of the BDU. For Settlements, where dual TLFs apply, the primary TLF is applied to all energy (load and generation) when the Net Energy Flow of the ConnectionPointID in the interval is negative (net load). ✓
processed_at DateTime64(3) ✓
source_zip String ✓

Schema Versions

Version Rows Size
af53c352 133,067 890.14 KiB

Last updated: 2025-12-10 08:00:07